Portable Test Hook Probe To Testing Whether The Dangerous Electric Parts Can Be Touched 180±0.05
Portable Test Hook Probe To Testing Whether The Dangerous Electric Parts Can Be Touched 180±0.05
- Model:
Portable Test Hook Probe To Testing Whether The Dangerous Electric Parts Can Be Touched 180±0.05
IEC 60065:2014 clause 9.1.1.7 Anti Shock Probe Experiment Device CT-2
Standard:
Conforms to IEC 60065:2014 clause 9.1.1.7, figure 4, 12.7.4
Application:
It is used to test the enclosure mechanical strength of audio, video and similar electronic apparatus.
Test sample:
Audio, video and similar electronic apparatus.
Feature:
It is used to test whether the dangerous electric parts can be touched. The test hook is “hooked” into vents and seams in the enclosure & then pulled with a force 20±2 N last for 10s. The hook has a hole at its long end, for use in conjunction with a PFI series Force Gauge. It is made entirely of stainless steel.
Parameters:
Name/Model | Test hook probe /HT-I18 |
Probe length | 180±0.05 |
Probe width | 8±0.15 |
Hook length | 5±0.05 |
Test hook thickness | 1±0.15 |
Test hook angle | 90° |
Material | Stainless steel |
Picture for reference :