IEC60695-2-10 IEC Test Equipment Glow Wire Tester PLC Control For Fire Hazard Testing With Infrared Remote Control
IEC60695-2-10 IEC Test Equipment Glow Wire Tester PLC Control For Fire Hazard Testing With Infrared Remote Control
- Model:
IEC60695-2-10 IEC Test Equipment Glow Wire Tester PLC Control For Fire Hazard Testing With Infrared Remote Control
IEC60695-2-10 IEC Test Equipment Glow Wire Tester PLC Control For Fire Hazard Testing With Infrared Remote Control
Standard
IEC60695-2-10, IEC60695-2-11, IEC60695-2-12, IEC60695-2-13, UL746A.
Application
This device simulates the thermal stress test of glowing component or heat source like overload resistance or ignition source which is caused in a short time. It is suitable for electric and electronic products, household appliances and other material to do fire hazard testing. It is also used in the No flame ignition source fire test to test initiation temperature and flammability index of related glowing filament.
Test sample
Electrical equipment and its components and parts, solid electrical insulating materials and other solid combustible materials.
Feature
Test principle: the glowing filament whose material and shape is required(Ni77/Cr20) is heated to the testing temperature of 550 ℃ ~ 960 ℃ for 1 min by using the glow wire tester with large current. Then using required pressure (0.95N) vertically burns the test sample for 30s. By observing whether the test sample and bedding object ignite or the burning time, the users can judge the ignition danger of electric and electronic products. It is used for the ignition test, ignition temperature (GWIT) test, flammability test and flammability index (GWFI) test of solid insulating material and other solid combustible material.
Parameters
ParametersModel | GW-2(Touch screen) |
Working voltage | 220V/50Hz |
Control operation mode | PLC control, 7 inch color touch screen operation, with infrared remote control |
Remote control | infrared remote control outside the cabinet operates the equipment when door are closed |
Flame detect | Flame sensor indicate start/stop burning |
Test data | 20 test data stored in PLC |
Glowing filament | Ф4mm ± 0.04mm (> 77 % Ni/20 ± 1 % Cr) special standard ring shape, horizontal standing |
Specimen pressure on glowing filament | 0.95N±0.1N |
Maximum depth of heating | 7mm ± 0.5mm |
Specimen movement speed | 10mm /s ~ 25mm /s |
Temperature calibration | Calibration temperature:960°±10°C, the hot wire by electric heating |
Thermocouple: RS imported 1mm armour nickel-chromium/nickel/ nickel aluminum K-Thermocouple, temperature resistance 1100° | |
Silver foil: purity 99.8%, size: 4mm², thickness:0.06mm | |
Tray | A layer of silk paper (12~30g/m³) is covered on the 10mm thick pine board, with a distance of 200±5mm below the test sample |
Test chamber | >0.5 cube, sample distance from the inside of the box is greater than 100mm, black yogon background, background illuminance ≤ 20Lx,with exhaust fan |
Testing time | 30s±1s |
Test procedure | The test sample is driven by the car and automatic run, the car will return automatically after glow-wire entered the test sample of 7mm |
Lighting | Equip with lighting in the test chamber, with control |
Dimension | 1100*550*1200mm, 140kg |
Picture for reference
IEC Test Equipment
IEC Test Equipment
IEC Test Equipment