IEC60695-2-10 IEC Test Equipment Glow Wire Tester PLC Control For Fire Hazard Testing With Infrared Remote Control

IEC60695-2-10 IEC Test Equipment Glow Wire Tester PLC Control For Fire Hazard Testing With Infrared Remote Control

  • Model:

IEC60695-2-10 IEC Test Equipment Glow Wire Tester PLC Control For Fire Hazard Testing With Infrared Remote Control

 

Standard

 

IEC60695-2-10, IEC60695-2-11, IEC60695-2-12, IEC60695-2-13, UL746A.

 

Application

 

This device simulates the thermal stress test of glowing component or heat source like overload resistance or ignition source which is caused in a short time. It is suitable for electric and electronic products, household appliances and other material to do fire hazard testing. It is also used in the No flame ignition source fire test to test initiation temperature and flammability index of related glowing filament.

 

Test sample

 

Electrical equipment and its components and parts, solid electrical insulating materials and other solid combustible materials.

 

Feature

 

Test principle: the glowing filament whose material and shape is required(Ni77/Cr20) is heated to the testing temperature of 550 ℃ ~ 960 ℃ for 1 min by using the glow wire tester with large current. Then using required pressure (0.95N) vertically burns the test sample for 30s. By observing whether the test sample and bedding object ignite or the burning time, the users can judge the ignition danger of electric and electronic products. It is used for the ignition test, ignition temperature (GWIT) test, flammability test and flammability index (GWFI) test of solid insulating material and other solid combustible material.

 

Parameters

 

ParametersModelGW-2(Touch screen)
Working voltage220V/50Hz
Control operation mode

PLC control, 7 inch color touch screen operation,

with infrared remote control

Remote controlinfrared remote control outside the cabinet operates the equipment when door are closed
Flame detectFlame sensor indicate start/stop burning
Test data20 test data stored in PLC
Glowing filamentФ4mm ± 0.04mm (> 77 % Ni/20 ± 1 % Cr) special standard ring shape, horizontal standing
Specimen pressure on glowing filament0.95N±0.1N
Maximum depth of heating7mm ± 0.5mm
Specimen movement speed10mm /s ~ 25mm /s
Temperature calibrationCalibration temperature:960°±10°C, the hot wire by electric heating
Thermocouple: RS imported 1mm armour nickel-chromium/nickel/ nickel aluminum K-Thermocouple, temperature resistance 1100°
Silver foil: purity 99.8%, size: 4mm², thickness:0.06mm
TrayA layer of silk paper (12~30g/m³) is covered on the 10mm thick pine board, with a distance of 200±5mm below the test sample
Test chamber>0.5 cube, sample distance from the inside of the box is greater than 100mm, black yogon background, background illuminance ≤ 20Lx,with exhaust fan
Testing time30s±1s
Test procedureThe test sample is driven by the car and automatic run, the car will return automatically after glow-wire entered the test sample of 7mm
LightingEquip with lighting in the test chamber, with control
Dimension1100*550*1200mm, 140kg
 

Picture for reference

 

 


IEC Test Equipment

IEC Test Equipment

IEC Test Equipment