KP-1060 Capacitor Discharge Tester for IEC 62368, IEC 60335-1 and IEC 60601-1 Residual Voltage Tests
News 2026-05-21 22
KP-1060 Capacitor Discharge Tester is built for residual voltage and capacitor discharge safety tests under IEC 62368, IEC 60335-1 and IEC 60601-1, with a 0-300V test range, 10A rated current, 3KVA load capacity, 100±5MΩ measuring resistance and 1s / 2s power-off timing modes.
Why Residual Voltage Testing Is Critical
After a product is disconnected from mains power, stored energy in X capacitors and internal circuits can still create an electric shock risk. For power adapters, household appliances, medical electrical equipment and information technology products, the discharge time and remaining voltage must be verified before certification testing moves forward.
The KingPo KP-1060 Capacitor Discharge Tester gives laboratories a controlled way to disconnect power at a defined point and capture the voltage decay curve. This helps engineers confirm whether the product can reduce accessible voltage within the required time limit.
Standards and Test Applications
KP-1060 is used for discharge verification linked to major product safety standards, including IEC 62368 for audio/video and ICT equipment, IEC 60335-1 for household appliances, and IEC 60601-1 for medical electrical equipment. It is suitable for R&D labs, factory quality teams and third-party test laboratories that need repeatable residual voltage data.
Key Technical Parameters
| Model | KP-1060 Capacitor Discharge Tester |
| Applicable standards | IEC 62368, IEC 60335-1, IEC 60601-1 |
| Test voltage range | 0-300V |
| Rated current | 10A |
| Load capacity | 3KVA |
| Measuring resistance | 100±5MΩ |
| Power-off timing | 1s and 2s test modes |
| Main test target | Residual voltage after product disconnection |
KingPo Engineer's Field Advice
In real laboratory work, the most common error comes from unstable power-off timing. If the tester disconnects at a random phase point, or if the probe resistance is not controlled, the same product can show different residual voltage values in repeated tests. This is especially noticeable on products with X capacitors or power supply filters.
KP-1060 addresses this by combining fixed 1s and 2s timing modes with a 100±5MΩ measuring resistance path. The design helps reduce operator timing error and keeps the discharge measurement condition consistent. For busy safety labs, this repeatability makes it easier to compare engineering samples, confirm design changes and prepare cleaner certification records.
Recommended Laboratory Workflow
- Confirm the product rating, test standard and required discharge time before wiring.
- Set the KP-1060 test voltage within the 0-300V range according to the sample requirement.
- Select the correct 1s or 2s timing mode based on the clause being checked.
- Run several cycles to verify whether the residual voltage result is stable.
- Record peak voltage, discharge curve behavior and final residual voltage for the test report.
Who Should Use KP-1060
This tester is suitable for manufacturers of power supplies, household appliances, medical devices, lighting products, chargers, control boards and other electrical products that include capacitors connected to mains circuits. It helps teams find discharge problems before formal compliance testing, reducing redesign time and sample rejection risk.
KingPo can support laboratories with equipment selection, test method discussion and configuration advice based on the target standard and product type.
Related articles
- Revolutionizing Pilots: The Advanced Pil Test Device Where Innovation Meets Safety
- Who Is a Supplier Motor Tester?
- Unveiling the IP6k9k: A Comprehensive Insight
- The Essential Guide to Bending Resistance Testing Devices
- The Essential Guide to Bursting Strength Testers
- Best Cycle Thread Screws Guide
- Surgical Sale: A Dive into Various Instruments and Their Uses
- The Essential Role of Syringe Testing Instruments in Modern Healthcare