 Equipment Overview: 
 This temperature rise test system meets the standard requirements of IEC 62196-1: 2020 clause 24, IEC 60309-1: 2012 clause 22, etc. 
   
 Equipment Principle: 
 The temperature rise test system consists of an electric voltage regulator, a current transducer, a PLC programmable controller, a current sensor, a humanized touch screen and a movable chassis. It can stably output the test current, and eliminate the influence to the test current caused by the fluctuation of the power supply voltage, the connecting wire or the copper bar, and the resistance value of the sample, and improve the accuracy of the test result. The power supply have functions of low loss, high efficiency, easy operation, complete control and detection. The touch screen can display the current value and the temperature values of each temperature measurement points in real time. The temperature value can be recorded every 2 seconds and report can be generated, which can be stored in a USB flash drive and copied to a computer for viewing and printing. 
   
 Technical Parameters: 
 
   
 
              
It is suitable for detecting the temperature rise test after the charging pile interface plug and socket pass the rated current, and assessing the heating of the surface of the electrical accessories when the load current is connected, and whether the temperature rise of the terminal meets the requirements of the standard.
 
Temperature Measurement Point 
8 channels 
 
Operation Method 
Color humanized touch interface 
 
Output Constant Adjustable Current 
AC 0.50~50.00~400.0A(Level 1, can be set) 
 
Output Current Mode 
Continuous/ Intermittent 
 
Load Test Output Voltage 
Below AC 5V 
 
Current Resolution 
0.1A 
 
Ammeter Accuracy 
±1%±3 bytes 
 
Voltmeter Accuracy 
±1%±3 bytes 
 
Continuous Mode Test Time 
0.01~99.99 hours 
 
Intermittent Mode Test Time 
0.01~99.99 hours 
 
Intermittent Mode Test Cycles 
1~99999 cycles, automatic shutdown when the test cycles reach to the preset value 
 
Temperature Measurement Range 
0~400°C, accuracy 0.3% reading + 1°C; resolution: 0.1°C 
 
Temperature Data Acquisition 
Configure RS232 communication interface and data record interface 
 
Temperature Scanning Speed 
1 to 255 seconds all channels 
 
Temperature Data Record 
The data can be stored U disk 
 
Temperature Measuring Thermocouple 
American Omega T-type 30AWG filament thermocouple, length 2 meters, a total of 8 pieces 
 
Power Supply 
Single phase AC220V±10%, 50/60Hz, 3KVA 
 
Equipment Dimensions and weight 
Approx. L 800mm* W 680mm* H1610mm, 125KG 