Products

Hair Care Appliance Swivel Connection Sliding Contacts Temperature Rise Test Equipment
Products Description
                     
 IEC60335-2-23 Electrical Hair Care Appliance Swivel Connection Sliding Contacts Temperature Rise Test Equipment 
   
 Product overview: 
   
 The swivel connection rotation testing equipment is special designed and manufactured according to IEC60335-2-23 clasue 11.101, it is used to examine the temperature rise performance of the sliding contacts of the swivel connection of hair & skin care appliances after a continuous rotating operation. 
   
 The test device adopts to PLC electrical control, 7-inch color touch screen intelligent operation system; servo motor controlling the test angle, high precision digital instrument, high performance digital frequency conversion, precise speed regulation, six number memory timer, multifunctional combined clamps, center gauge of rotation, bending angle adjustable, 4kw output power, can also supply load current to test sample (1.25 times of test sample’s rated current). Test times (maximum of 999999 times), test speed can be preset; it has electric current detection function. 
   
 Technical Characteristics: 
   
 Universal fixtures for skin & hair care appliances, 1 set 
 Test procedures (extracted from IEC 60335-2-23: 2019 clause 11.101): 
   
 Appliances incorporating a swivel connection are positioned with their major axis horizontal, the supply cord hanging vertically. A pull force of 1N is applied to the supply cord. 
   
 The appliance is supplied at rated voltage, the current being 1.25 times the rated current. 
   
 The appliance is rotated about its major axis at a rate of approximately 50r/min, the direction of rotation being reversed every 20 revolutions. The test is carried out for 1500 revolutions. 
   
 The temperature rise of the sliding contacts shall not exceed 65 K. (Measured with the infrared thermometer that comes with this equipement). 
   
 How to install the test sample on the proper position? 
   
 Make the end of the power cord of the test sample is outwards and the other end of the test sample without power cord to be clamped on the fixture, the center of the sample should be consistent with the center of the fixture, and should not damage the sample. The power cord sheath and wire vertical downward, then tie the power cable in the appropriate position in order to hang the weight. The power cord sheath can be clamped tighten or not according to the actual situation. Shown as following: 
   
 
   
   
 
              
 
Flexing or swivel angle 
0-360°, Can be preset 
 
Flexing or swivel speed 
0~60 rpm, can be preset 
 
Test times 
0~999999 times, can be preset and displayed 
 
Power 
Match client's local power supply requirements 
 
Control 
PLC programmable control 
 
Drive 
Servo motor 
 
Operation 
7 inch touch screen 
 
Max. output power 
5KW, can be customized 
 
Output voltage 
0~250V, can be customized 
 
Max. output current 
16A, can be customized 
 
Max. carrying capacity 
15kg, can be customized 
 
Test station 
1 station, can be customized 
 
Specimen fixture 
 
 
Temperature Measuring 
Hand-held infrared thermometer, -50°C~380°C 
 
Load weights 
1N*1 
 
Standards 
IEC60335-2-23 clause 11.101 