Products

DIN EN ISO 6270-2 Motor Vehicle Components Condensation Test Equipment
Products Description
                     
 DIN EN ISO 6270-2 Motor Vehicle Components Condensation Test Equipment 
   
 Product overview For Motor Vehicle Components Condensation Test Equipment: 
 
This condensation test chamber meets the condensation test requirements of .VW 80000-2017,DIN EN ISO 6270-2, GS95011-4-2004, DIN 50017, etc. 
 It simulates the condensation on electronic modules in motor vehicles. It is meant to evaluate the robustness of electronic modules with respect to condensation. 
 4 movable casters 
   
 Using MCGS programmable temperature and humidity controller (7-inch 16-bit true color touch screen); English menu operation mode, 120 groups memory program, each program group contains 1200 program segments, all loops, up to 999 times. Controller: The controller with English display has the function of self-diagnosis, prompts the cause of failure and treatment method, records test data and process, and has a standard RS232 or U disk communication interface. 
   
 
   
 
   
 
   
   
   
   
              
 
Technical parameters For Motor Vehicle Components Condensation Test Equipment:
 
Size 
Working area 
600*500*830mm(W*D*H) 
 
External size 
Approx. 1200*750*1300mm(W*D*H) 
 
Performance 
Temperature range 
Ambient~60℃ (common used temperature: 38℃/49℃/60℃) 
 
Temperature fluctuation 
≤1℃ (≤±0.5℃, tested according to GB/T5170-2008) 
 
Temperature accuracy 
0.1 ℃ 
 
Temperature deviation 
±2℃ 
 
Humidity range 
100%RH (+0%, -5%, during condensation) 
 
Heating rate 
≥10℃/30min (20KG steel with load, meeting the condensation test in VW80000-2013) 
 
Cooling rate 
≥65℃/75min (20KG steel with load, meeting the condensation test in VW80000-2013) 
 
Temperature and humidity measuring parts 
Use high-precision A-level PT100 temperature sensor for temperature measurement 
 
Heating method 
Electric heating, PID adjustment, actuator: solid state relay 
 
Heating system 
New-type ceramic heating frame, with heating wire imported from Germany in the middle, thick wire diameter, high temperature resistance, dry burning resistance 
 
Humidification system 
External humidification, the humidification tube adopts U-shaped design and over-temperature probe hole, 
 
Dehumidification system 
Using evaporator coil dew point temperature laminar flow contact dehumidification method 
 
Water supply system 
The humidification water supply adopts automatic control, and the residual water can be recycled, saving water and reducing consumption 
 
Cooling System 
Fully enclosed Tecumseh compressor imported from France, using R404 and R23 DuPont environmentally friendly refrigerant 
 
Wind tunnel 
Forced circulating air duct to ensure uniform temperature in the working room; heaters, coolers, and temperature sensors are installed in the air duct 
 
Condensate outlet 
With outlet holes for studio condensate and unit condensate 
 
Timing range 
1~9999 mins/hours 
 
Materials 
Outer wall material 
A3 iron plate sprayed 
 
Inner wall material 
SUS304 Stainless steel plate 
 
Insulation material 
Rigid polyurethane foam 
 
Observation window 
Three-layer explosion-proof tempered glass window 
 
Lead hole 
2 Φ100mm lead holes, with cover and soft plug, located on the left and right walls of the chamber 
 
Sample rack 
2PCS, SUS304 stainless steel material, adjustable spacing storage track, sample rack can be adjusted up and down according to needs, evenly bearing 30KG/layer. 
 
Light 
There is a lighting lamp on the top of the observation window, which is controlled by the switch outside the door, which is convenient and clear to observation 
 
Movable casters 
 
 
Humidification tank 
High quality 304 stainless steel water tank 
 
Control element 
 
 
Supply voltage 
220v (single-phase three-wire, make a 40a air switch separately, the air switch must have terminals, the power line should be more than 4 square meters; 50hz; power: 4kw 
 
Security system 
Studio 
Independent studio overheating protector; fan overheating protection 
 
Cooling System 
Compressor overpressure; Compressor overcurrent; Compressor overheat; Discharge temperature protection 
 
Power Systems 
Power supply phase loss and phase sequence error protection; Leakage protection; Heater over-temperature protection; Heater short-circuit and other over-current protection 
 
Other 
Test box shell grounding protection 
 
Installation environment 
The location of the equipment should be reserved for the floor drain or the drain pipe interface. The drain pipe should be divided into 4 pipes, and the mouth of the drain pipe should be flat with the ground. 
 
Temperature: 20℃~28℃, relative humidity: ≤85%, air pressure: 86kpa~106kpa 
 
The installation site should be flat and well ventilated. There is no strong vibration around the equipment, and there is no strong electromagnetic field around the equipment 
 
There are no flammable, explosive, corrosive substances and dust around the equipment. Appropriate use and maintenance space is left around the equipment 