IEC 60335 Clause 7 Dual Station Label Marking Abrasion Test Apparatus
Products Description
                     
   
 IEC 60335 Dual Station Label Marking Abrasion Test Apparatus 
   
 Standards For Dual Station Label Marking Abrasion Test Apparatus: 
   
 This label marking abrasion test apparatus conforms to IEC 60335-1 clause 7.14, IEC 60065:2014 clause 5.1, IEC 60950:2013 clause 1.7.11, IEC 60669-1 clause 8.9. 
   
 Technical parameters For Dual Station Label Marking Abrasion Test Apparatus: 
   
 Maintenance Notes For Dual Station Label Marking Abrasion Test Apparatus: 
   
 1 The instrument must be placed on a stable surface before use. 
 2 It is not allowed to move the machine during use. 
 3 Select the appropriate power supply voltage, should not be too high, to avoid burning the instrument. 
 4 If the instrument works abnormal, please contact with us for timely processing. 
 5 The instrument must be used in a good ventilation environment. 
 6 Please add lubricating oil to the mechanical transmission part in time due to the large operating load of each component of the button mechanism. 
 7 After each test is completed, operator should clean the machine. 
 8 The control box part must be wiped with a dry cloth. 
   
 Troubleshooting For Dual Station Label Marking Abrasion Test Apparatus: 
   
 1 If the POWER is turned on, the instrument is not powered on or the power indicator is not light: if the power indicator is damaged, replace the indicator; if there is no power output at the power output terminal, please check the power cord or power socket-outlet. 
 2 If the power is turned on, the power indicator lights, but the machine does not work when operator presses the SWITCH button. Please check whether there is a disconnection. If there is a disconnection, please connect it in time. If there is no disconnection of the relay, indicating that the counter is damaged, the counter should be replaced in time. 
 3 When the number of times set on the counter is finished, but the motor does not stop working, indicating that the counter is damaged. 
 4 If the power indicator light is on but the counter has no display, it means that the counter is damaged and the counter needs to be replaced. 
   
 Configuration 
   
 
   
 
   
   
              
 
Test stations 
Two stations 
 
Test stroke 
10-60mm, adjustable(Manually adjustable) 
 
Speed 
5-60 times /min, adjustable 
 
Counter 
0-9999 adjustable 
 
Weight 
Two pieces of 10g, 20g,50g, 100g, 200g, 500g 
 
Voltage 
AC 220V, 50Hz 
 
Machine size: 
500*300*550mm 
 
No.: 
Name 
Unit 
Quantity 
 
1 
Main device 
Label Marking Abrasion Test Apparatus 
Set 
1 
 
2 
Accessory 
Petroleum spirit/ alcohol abrasion test fixtures 
PCS 
2 
 
Rubber head abrasion test fixtures 
PCS 
2 
 
Pencil abrasion test fixtures 
PCS 
2 
 
Cotton cloth 
Pack 
1 
 
Rubber head 
PCS 
2 
 
Pencil 
PCS 
2 
 
3 
Document 
User manual 
Copy 
1 
 
Certificate of quality 
Copy 
1 
 
Warranty card 
Copy 
1 