Products

IEC 60320-1 Clause 14.2 Figure B.1 Steam Sterilizer Moisture Resistance Test Apparatus
Products Description
                     
 IEC 60320-1 Clause 14.2 Figure B.1 Steam Sterilizer Moisture Resistance Test Apparatus 
   
   
 Product information: 
   
 The spillage test apparatus is designed and manufactured according to IEC 60335-2-15 clause 15.2 figure 101, and IEC60320-1 clause 14.2 figure B.1. 
 It is intended for checking the weight of the protective measures against liquid overflow to ensure that the structure of the plug-in connector (cordless electric kettle) is not affected by liquid when it is installed in an alternative voltage base following the manufacturer’s installation instructions. 
   
   
 Technical parameters: 
   
 30ml water containing 1% of NaCl 
 (The solution should be prepared by user) 
 1. Sample clamping 
 According to the standard diagram below, place the sample directly under the funnel, and adjust the height of the funnel tray so that the bottom of the funnel is 200mm away from the sample surface. 
 
   
 2. Test liquid preparation 
 Prepare 30mL of a solution containing 1% sodium chloride and fill it with a test tube. 
   
 3. Connect the electrical strength equipment 
 Connect the base to the withstand voltage instrument according to the standard. 
   
 4. Test operation 
 Pour the solution in the test tube into the funnel manually within 2s and let it drip onto the sample. Then use the withstand voltage instrument to apply a test voltage of 2500V for the electrical strength test. Determine whether it is qualified according to the standard. 
   
 
   
 
   
 
   
   
              
 
Tube Diameter 
8 mm 
 
Tube Length 
30 mm 
 
Test Solution Volume 
30 ml 
 
Test Solution Type 
 
 
Distance from the lower end of tube to the appliance 
200 mm, adjustable 
 
Apparatus Material 
Plastic 