IEC 60065 Clause 7.1 Audio Video Test Equipment Hot Winding Resistance Meter Measuring Rang From 0.5 To 2000Ω

IEC 60065 Clause 7.1 Audio Video Test Equipment Hot Winding Resistance Meter Measuring Rang From 0.5 To 2000Ω

  • Model:

IEC 60065 clause 7.1 Hot Winding Resistance Meter RXDC-3/ RXDC-3A

 

Standard:Conforms to IEC 60065 clause 7.1, IEC60950, IEC60335-1 clause 11 Household and similar electrical appliances-safety-Part 1:General requirements.

 

Application:Used for the winding temperature measurement of various household appliances and completed products(such as air conditioners, refrigerators, electric fans, washing machines, etc.)and other small power motor and transformers.

 

Test sample:Household appliances.

 

Feature:Single channel or dual channel can be selected.

 

 

Parameters:

1.Measuring range:0.5~20~200~2000Ω

2. Measurement Accuracy:cold state ±0·1%READ+0·1%FS, thermal state ±0·15%READ+0·15%FS

3. Ambient temperature:Measuring range 0~ 50℃,Measurement Accuracy ± 0·5℃

4. Temperature Rise:Calculated according to the formula rise

5. Thermal resistance response time:<30 seconds

6. Experimental time:Maximum 99 hours 59 minutes 59 seconds,Accuracy ±0·1%

7. Winding temperature coefficient can be set to 0 ~ 999.9, all set parameters latched when power failure.

8. Instrument standard equipped serial port, can communicate with the computer serial

9. Testing software content: Record the temperature change data, display temperature curves, check printing.

10. Optional mini-printer, can print multi-channel temperature data timing, the print measurement time interval can be set by the user.

11. Standard equipped 25-pin parallel printer port, you can connect the printer directly to print test data; multi-channel temperature data can be regularly print, the measurement time interval can be set by the user.

12. Power supply:AC220V ±10%,50Hz /60Hz, Total power consumption<15W

13. Operating environment:Operating Temperature 25℃±15℃; Humidity 60%±30%